Thank you!

An Ooma AirDial Sales Representative will be in touch shortly.

866-839-5810

The Ooma Office Logo
Thank you
Ooma Enterprise

Get your custom quote.

Let’s talk and see how much you can save with Ooma AirDial.

We’ll follow up within a business day.

We’ll help you analyze whether Ooma AirDial is a good solution for your needs.

A custom quote will be generated.

Call Sales 866-839-5810

By clicking the “SUBMIT” button below:

I agree to Ooma’s Privacy Policy.

I agree to receive marketing, informational, or transactional phone calls or text messages from or on behalf of Ooma, Inc. regarding its products and services at the mobile phone number that I provided above. I understand my consent is not a condition of any purchase of any goods or services.

Fix error
Person building a POTS line replacement business case on a laptop

Generate Your Personalized POTS Line Replacement Business Case

Get the information needed to build your case for POTS replacement. Create a customized business case document that shows how much your organization can expect to save by replacing POTS lines with Ooma AirDial.

Red fire alarm pull station

Still using POTS lines? See where they still support critical systems.

Check POTS Readiness

Call sales at:
866-902-6765

Fire watch requirements when fire alarm monitoring is down

Publish Date: November 24, 2026
Author: Tonya Hottmann

Key Points:

  • A fire watch provides temporary patrols when required fire protection is impaired.
  • Lost fire alarm monitoring can require a fire watch, even if on-site alarms still sound.
  • Local fire authorities determine fire watch requirements, coverage and approvals.
  • Report monitoring failures promptly and coordinate repairs to limit outages and staffing costs.
  • End fire watch only after required testing, signal verification and any necessary authorization.

When a fire alarm loses its connection to the monitoring station, building owners can face immediate safety concerns, unexpected staffing costs and potential occupancy restrictions. An approved fire watch may be required until communications are restored.

Responding requires coordination among your facility team, alarm contractor, monitoring provider and local fire authority. Together, they must assess the failure, establish required safety measures and verify that repairs restore alarm reporting.

Understanding fire watch requirements can help your organization respond quickly—and recognize the importance of addressing unreliable alarm connections before an outage forces action.

What is a fire watch?

A fire watch is a temporary safety measure that assigns qualified personnel to patrol a building or affected area when required fire protection is impaired. Personnel look for fire hazards and signs of fire, alert occupants and notify the fire department if an emergency occurs.

The watch helps protect occupants while repairs are underway and must continue until the applicable requirements for ending it have been met.

A fire watch provides temporary protection during an impairment. It does not eliminate the need to repair the affected system.

Can a failed alarm communicator trigger a fire watch?

Yes. A failed communicator or lost monitoring connection can prevent required signals from reaching the supervising station. Depending on the impairment and applicable requirements, the authority having jurisdiction (AHJ) may require a fire watch or other protective measures.

The problem may involve:

  • A failed alarm communicator.
  • A telephone service outage.
  • Discontinued copper phone service.
  • Damaged or disconnected wiring.
  • A failure affecting another required communication path.

Your fire alarm contractor and monitoring provider should determine what has failed, which functions remain operational and whether required signals are reaching the monitoring station.

An alarm may sound inside the building even when signals cannot reach the monitoring station. Confirm that occupants receive the warning and that the monitoring station receives the required signals.

What do NFPA fire watch requirements say?

NFPA fire watch requirements depend on the applicable standard, adopted edition, occupancy and nature of the impairment.

Under applicable NFPA 101 provisions, a required fire alarm system that is out of service for more than four hours in a 24-hour period can require evacuation or an approved fire watch for those left unprotected.

Do not wait four hours to report a failure. Applicable fire codes may require immediate notification when a required fire protection system is out of service. The local fire authority may also require protective measures before that threshold.

Contact the AHJ promptly to confirm:

  • Whether the monitoring failure requires formal impairment procedures.
  • Whether a fire watch, evacuation or another safety measure is required.
  • Which areas need coverage and during what hours.
  • What training, patrol schedules and documentation are required.
  • What testing and approvals are needed to resume normal operations.

Can a fire watch affect building occupancy and safety?

Fire alarm impairment can put continued building occupancy at risk. Depending on the failure and local requirements, the fire authority may permit occupancy under an approved fire watch, restrict building use or require evacuation. [2]

For owners, the consequences can include staffing expenses, disrupted tenant operations and reduced access to affected spaces. A failed monitoring connection can also delay alarm reporting and emergency notification. A fire watch provides temporary protection during repairs, but the building must meet the authority’s safety requirements to remain occupied. [2, 3]

What should you do when alarm monitoring goes down?

1. Contact your monitoring provider

Confirm when communication was lost, which signals are affected and whether another approved path is still working. Ask the provider to document the outage and coordinate testing with your fire alarm contractor.

2. Notify the fire authority responsible

Follow the jurisdiction’s reporting process promptly, confirming required safety measures, occupant notifications and any restrictions on building use.

3. Arrange diagnosis and repairs

Have a qualified fire alarm contractor identify and address the failure. Involve your telephone or connectivity provider if the problem affects the alarm’s communication path. Track service tickets, repair estimates and the expected restoration time.

4. Put required protection in place

If fire watch is required, confirm personnel qualifications, patrol routes, coverage hours, communication equipment and documentation procedures. Arrange relief coverage to prevent gaps during breaks and shift changes.

5. Assign a response coordinator

Designate one person to track repairs, maintain records and coordinate with the monitoring provider, contractor and fire authority. Keep affected building personnel informed until the system is restored and normal operations are authorized.

Who can perform a fire watch?

Qualified building employees or an outside fire watch provider may perform the work, subject to local requirements and approval by the responsible fire authority.

Before assigning personnel, confirm any required training or credentials. Anyone conducting a fire watch should know the building layout, patrol route, evacuation procedures and how to contact emergency responders.

Do not assume employees can combine fire watch with their regular responsibilities. Where dedicated personnel are required, they must focus exclusively on fire watch duties.

What fire prevention measures are required?

Follow the approved fire watch plan for your property. Common fire prevention measures include:

  • Checking for ignition hazards and improperly stored flammable materials.
  • Identifying trash or combustible materials that create a hazard.
  • Keeping exits, corridors and stairways clear.
  • Confirming fire extinguishers remain accessible.
  • Checking that fire doors are not blocked open.
  • Watching for smoke, unusual odors or other signs of fire.

Personnel also need an approved, reliable way to notify the fire department and clear instructions for alerting occupants.

Confirm the required patrol frequency and areas to be covered under the approved plan. Do not assume occasional walkthroughs are sufficient.

How much can a fire watch cost?

Fire watch can turn an alarm communication failure into a significant staffing expense. The total depends on the hourly rate, number of personnel required and length of coverage.

Use this calculation to estimate direct labor:

Hourly rate/person × personnel on duty × coverage hours = staffing cost

Certified Fire Watch Services publishes estimated standard-market rates of $25–$40 per guard per hour. These are provider estimates, not an independently verified national average. [1]

The examples below calculate direct staffing costs for one or two positions covered continuously, 24 hours per day, using that published hourly range.

Coverage period One person on duty Two people on duty
24 hours $600–$960 $1,200–$1,920
72 hours $1,800–$2,880 $3,600–$5,760
Seven days $4,200–$6,720 $8,400–$13,440

Note: These totals are calculated examples based on the published $25–$40 hourly range, not quotes. Actual costs depend on the provider, property, required staffing and coverage hours, and any additional charges.

At those rates, each additional day of continuous fire watch adds $600–$960 per staffed position, before repairs, testing and other charges.

Assigning internal employees also adds costs, including overtime, coverage for their regular duties and lost productivity.

Across multiple properties, these expenses can add up quickly, making reliable alarm connectivity a priority for maintenance budgets and modernization planning.

What records should you keep?

Use your jurisdiction’s required forms or reporting platform to document the fire watch. Records commonly include:

  • Building name and address.
  • Reason for the fire watch.
  • Names of assigned personnel.
  • Shift start and end times.
  • Patrol times and areas covered.
  • Hazards identified and corrective actions taken.
  • Communications with the fire authority and monitoring provider.

Keep these records with repair reports, test results and any required authorization to end the fire watch as part of the system’s impairment documentation.

When can the fire watch end?

Follow the responsible fire authority’s requirements for restoring normal operation and ending the fire watch. After a monitoring failure, those steps may include:

  • Repairing or replacing the affected communication path.
  • Completing required testing with your alarm contractor.
  • Verifying that the monitoring station receives all required signals.
  • Submitting repair records and test results.
  • Obtaining authorization to end the fire watch, where required.

Completing repairs does not automatically mean patrols can stop. Confirm that all requirements have been met before releasing fire watch personnel.

Address alarm connectivity before an outage forces action

Include fire alarm connectivity in your maintenance budgets and modernization plans. Identify the service supporting each panel, review carrier notices and establish who will respond if communications fail.

If a panel depends on copper phone service scheduled for retirement, plan its replacement before service ends. Coordinate device compatibility, installation, testing and required approvals with your staff, contractors, monitoring provider and authority having jurisdiction.

Planning ahead gives your organization time to manage the transition and helps reduce the risk of a monitoring outage that requires emergency fire watch staffing.